Error Logs

Timestamp Error Message
2025-10-20T17:10:04.0000000 Unable to find parse start location. Make sure there is a desciption line that starts with `<select:`.
{"TaxCodeId":"47","TaxRate":0.057083,"TaxCodeName":"Eddy County","Id":9751,"TimeStamp":"2025-10-15T17:18:53Z","wellName":"\u003CSelect Unit\u003E","Username":"jose","otHours":0.0,"NoteText":"By: jose\n\nVCS-1797 WINE MIXER 21/20 BATTERY #1 : \n\nREGULAR MAINTENANCE \n\nJob Date: 2025-10-15 17:18:53 \n\nUnit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 15; Drive Time: 2.50 hours; Site Hours: 7.0 hours; Job Hours: 9.5 hours;\n\nVCS-1797 :\n10/15/2025\nDrove to the location and installed a 300 HP VFD. We measured the wires, cut them, striped them, and crimped the terminals. Then we connected the wires to the VFD.\nPARTS\n1 300 HP \n3 4/0 TERMINAL\n7 3/0 TERMINAL\n1 2/0 TERMINAL\n\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n1.0 ea 9122 GX3-300HP 3600RPM W/MODS Non C-face\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n3.0 ea 8387 4/0 AWG COP 1H Lug\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n7.0 ea 8386 3/0 AWG 1H Lug\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n1.0 ea 8385 2/0 AWG COP 1H lug\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n1.0 ea 9200 Varnished Cambric Tape 2510-1X36YD\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n1.0 ea 9062 130C splicing tape\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n1.0 ea 10193 Super 88 electrical tape\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n1.0 ea 9224 300/350HP VFD Hitachi","SiteHours":7.0,"DriveTime":2.5,"Mileage":90.0,"parts":[{"commentNum":"107027","partNum":"9122","partName":"GX3-300HP 3600RPM W/MODS Non C-face","quantity":1.0,"engUnit":"ea","unitPrice":19555.0,"markup":38.5},{"commentNum":"107027","partNum":"8387","partName":"4/0 AWG COP 1H Lug","quantity":3.0,"engUnit":"ea","unitPrice":9.44,"markup":38.5},{"commentNum":"107027","partNum":"8386","partName":"3/0 AWG 1H Lug","quantity":7.0,"engUnit":"ea","unitPrice":8.31,"markup":38.5},{"commentNum":"107027","partNum":"8385","partName":"2/0 AWG COP 1H lug","quantity":1.0,"engUnit":"ea","unitPrice":7.68,"markup":38.5},{"commentNum":"107027","partNum":"9200","partName":"Varnished Cambric Tape 2510-1X36YD","quantity":1.0,"engUnit":"ea","unitPrice":67.39,"markup":38.5},{"commentNum":"107027","partNum":"9062","partName":"130C splicing tape","quantity":1.0,"engUnit":"ea","unitPrice":32.88,"markup":38.5},{"commentNum":"107027","partNum":"10193","partName":"Super 88 electrical tape","quantity":1.0,"engUnit":"ea","unitPrice":8.19,"markup":38.5},{"commentNum":"107027","partNum":"9224","partName":"300/350HP VFD Hitachi","quantity":1.0,"engUnit":"ea","unitPrice":15237.5,"markup":38.5}],"Total":48468.25504999999,"CustomerId":"356","ServiceId":"141","DriveTimeId":"156","MileageId":"143","ServiceRate":87.9,"DriveTimeRate":67.96,"MileageRate":1.4,"ItemId":"139"}
By: jose VCS-1797 WINE MIXER 21/20 BATTERY #1 : REGULAR MAINTENANCE Job Date: 2025-10-15 17:18:53 Unit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 15; Drive Time: 2.50 hours; Site Hours: 7.0 hours; Job Hours: 9.5 hours; VCS-1797 : 10/15/2025 Drove to the location and installed a 300 HP VFD. We measured the wires, cut them, striped them, and crimped the terminals. Then we connected the wires to the VFD. PARTS 1 300 HP 3 4/0 TERMINAL 7 3/0 TERMINAL 1 2/0 TERMINAL EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 1.0 ea 9122 GX3-300HP 3600RPM W/MODS Non C-face EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 3.0 ea 8387 4/0 AWG COP 1H Lug EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 7.0 ea 8386 3/0 AWG 1H Lug EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 1.0 ea 8385 2/0 AWG COP 1H lug EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 1.0 ea 9200 Varnished Cambric Tape 2510-1X36YD EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 1.0 ea 9062 130C splicing tape EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 1.0 ea 10193 Super 88 electrical tape EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 1.0 ea 9224 300/350HP VFD Hitachi
at AwcConnect.Services.QuickBooksInvoiceService.SubmitInvoice(Invoice invoice) in C:\Users\johnc\source\repos\AwcConnect\Services\QuickBooksInvoiceService.cs:line 37
2025-10-20T16:58:05.0000000 BadRequest. Details: Duplicate Document Number Error : You must specify a different number. This number has already been used. DocNumber=41716 is assigned to TxnType=Invoice with TxnId=128210 ,
{"TaxCodeId":"47","TaxRate":0.0525,"TaxCodeName":"Lea County","Id":9713,"TimeStamp":"2025-10-16T08:01:18Z","wellName":"VCS-1475 NORTH WILSON DEEP UNIT BATTERY","Username":"brett","otHours":0.0,"NoteText":"By: brett\n\nVCS-1475 NORTH WILSON DEEP UNIT BATTERY : \n\nREGULAR MAINTENANCE \n\nJob Date: 2025-10-16 08:01:18 \n\nUnit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 36; Drive Time: 2.0 hours; Site Hours: 2.50 hours; Job Hours: 4.5 hours;\n\nVCS-1475 :\n10-16 unit was going down on high discharge temp because the oil was contaminated again so i drove to location found ty had the unit drained and half way broken down so i helped him take the coaleser lid off on the unit then he flushed the unit while i changed out the 2 coaleser filters on the 2 vessels next to the unit, after he got down flushing it we reconnected the oil hoses an changed out the thermostat with a new one then changed the oil filters an the coaleser fitler then added 35 gallons of 180 to the coaleser an started the unit up, we purged the unit of O2 then washed the skid off then made sure the thermostat was opening up and checked all other operations, from there i drove home for the day. \n\n35 gallons 180 \n3 1550 \n2 1849 \n1 230 thermostat \n1/2 box soaker pads \n\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n35.0 gal 9956 Syncomp PG -180 Plus Screw oil\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n3.0 ea 7031 Filter, Coalescer NG20/21 2nd Gen Tank 311960\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n2.0 ea 7308 Filter, Hydraulic Oil. Used for NG21\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n1.0 ea 11185 230F Thermostatic Element Only\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n50.0 ea 8436 990140 Grey Soaker Pads","SiteHours":2.5,"DriveTime":2.0,"Mileage":86.0,"parts":[{"commentNum":"107045","partNum":"9956","partName":"Syncomp PG -180 Plus Screw oil","quantity":35.0,"engUnit":"gal","unitPrice":46.24,"markup":38.5},{"commentNum":"107045","partNum":"7031","partName":"Filter, Coalescer NG20/21 2nd Gen Tank 311960","quantity":3.0,"engUnit":"ea","unitPrice":736.32,"markup":38.5},{"commentNum":"107045","partNum":"7308","partName":"Filter, Hydraulic Oil. Used for NG21","quantity":2.0,"engUnit":"ea","unitPrice":175.0,"markup":38.5},{"commentNum":"107045","partNum":"11185","partName":"230F Thermostatic Element Only","quantity":1.0,"engUnit":"ea","unitPrice":81.0,"markup":38.5},{"commentNum":"107045","partNum":"8436","partName":"990140 Grey Soaker Pads","quantity":50.0,"engUnit":"ea","unitPrice":0.8,"markup":38.5}],"Total":5953.2285999999995,"CustomerId":"356","ServiceId":"141","DriveTimeId":"156","MileageId":"143","ServiceRate":87.9,"DriveTimeRate":67.96,"MileageRate":1.4,"ItemId":"139"}
By: brett VCS-1475 NORTH WILSON DEEP UNIT BATTERY : REGULAR MAINTENANCE Job Date: 2025-10-16 08:01:18 Unit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 36; Drive Time: 2.0 hours; Site Hours: 2.50 hours; Job Hours: 4.5 hours; VCS-1475 : 10-16 unit was going down on high discharge temp because the oil was contaminated again so i drove to location found ty had the unit drained and half way broken down so i helped him take the coaleser lid off on the unit then he flushed the unit while i changed out the 2 coaleser filters on the 2 vessels next to the unit, after he got down flushing it we reconnected the oil hoses an changed out the thermostat with a new one then changed the oil filters an the coaleser fitler then added 35 gallons of 180 to the coaleser an started the unit up, we purged the unit of O2 then washed the skid off then made sure the thermostat was opening up and checked all other operations, from there i drove home for the day. 35 gallons 180 3 1550 2 1849 1 230 thermostat 1/2 box soaker pads EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 35.0 gal 9956 Syncomp PG -180 Plus Screw oil EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 3.0 ea 7031 Filter, Coalescer NG20/21 2nd Gen Tank 311960 EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 2.0 ea 7308 Filter, Hydraulic Oil. Used for NG21 EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 1.0 ea 11185 230F Thermostatic Element Only EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 50.0 ea 8436 990140 Grey Soaker Pads
at Intuit.Ipp.Exception.IdsExceptionManager.HandleException(IdsException idsException) at Intuit.Ipp.DataService.DataService.Add[T](T entity) at AwcConnect.Services.QuickBooksInvoiceService.SubmitInvoice(Invoice invoice) in C:\Users\johnc\source\repos\AwcConnect\Services\QuickBooksInvoiceService.cs:line 201
2025-10-20T16:57:56.0000000 BadRequest. Details: Duplicate Document Number Error : You must specify a different number. This number has already been used. DocNumber=41716 is assigned to TxnType=Invoice with TxnId=128210 ,
{"TaxCodeId":"47","TaxRate":0.057083,"TaxCodeName":"Eddy County","Id":9712,"TimeStamp":"2025-10-17T08:09:44Z","wellName":"VCS-1513 John Denver/ Mocking Bird 15/14 Fed Com #521H","Username":"brett","otHours":0.0,"NoteText":"By: brett\n\nVCS-1513 John Denver/ Mocking Bird 15/14 Fed Com #521H : \n\nREGULAR MAINTENANCE \n\nJob Date: 2025-10-17 08:09:44 \n\nUnit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 36; Drive Time: 2.0 hours; Site Hours: 6.0 hours; Job Hours: 8.0 hours;\n\nVCS-1513 :\n10-17 unit was called in for having a bad screw so i drove to the shop filled up on oil and materials then dumped my waste oil and loaded up a G14 screw in my truck then fueled up an drove to location, an the way i had to stop an changed the tire on the crane truck after that we got too location an found that the unit was just pm so i drianed 3 gallons of oil from the coaleser then broke the unit down then pulled the inlet pipng off the unit and then the bad screw both motor an screw hubs were tore up along with the spider so i installed an new spider an hub on the motor then we prepped the new screw we found that the G14 hub key was broken so i drove to the woodford to grab a new key from issac then drove back to location finished prepping the screw an got it set on location, after that the crane truck waited on issac to show up to shim the screw and i left to another job. \n\n1 150 motor hub \n1 g14 screw hub \n1 g14 spider \n1 rebuilt G14 screw\n\n\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n1.0 ea 5569 Hub 150 HP Motor Side SCG14 \n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n1.0 ea 5571 Spider SCG14 150 HP\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n1.0 ea 5570 Hub Screw Side SCG14\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n1.0 ea 9341 Screw Rebuild SCG14\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n25.0 gal 7922 Syncomp PG-220\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n1.0 ea 7308 Filter, Hydraulic Oil. Used for NG21\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n1.0 ea 9753 Silicone RTV 8oz Red\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n1.0 sq ft 9001 Gasket Material","SiteHours":6.0,"DriveTime":2.0,"Mileage":102.0,"parts":[{"commentNum":"107141","partNum":"5569","partName":"Hub 150 HP Motor Side SCG14 ","quantity":1.0,"engUnit":"ea","unitPrice":94.55,"markup":38.5},{"commentNum":"107141","partNum":"5571","partName":"Spider SCG14 150 HP","quantity":1.0,"engUnit":"ea","unitPrice":22.5,"markup":38.5},{"commentNum":"107141","partNum":"5570","partName":"Hub Screw Side SCG14","quantity":1.0,"engUnit":"ea","unitPrice":111.0,"markup":38.5},{"commentNum":"107141","partNum":"9341","partName":"Screw Rebuild SCG14","quantity":1.0,"engUnit":"ea","unitPrice":3650.0,"markup":38.5},{"commentNum":"107141","partNum":"7922","partName":"Syncomp PG-220","quantity":25.0,"engUnit":"gal","unitPrice":40.17,"markup":0},{"commentNum":"107141","partNum":"7308","partName":"Filter, Hydraulic Oil. Used for NG21","quantity":1.0,"engUnit":"ea","unitPrice":175.0,"markup":38.5},{"commentNum":"107141","partNum":"9753","partName":"Silicone RTV 8oz Red","quantity":1.0,"engUnit":"ea","unitPrice":21.0,"markup":38.5},{"commentNum":"107141","partNum":"9001","partName":"Gasket Material","quantity":1.0,"engUnit":"sq ft","unitPrice":22.0,"markup":38.5}],"Total":6677.2792500000005,"CustomerId":"356","ServiceId":"141","DriveTimeId":"156","MileageId":"143","ServiceRate":87.9,"DriveTimeRate":67.96,"MileageRate":1.4,"ItemId":"139"}
By: brett VCS-1513 John Denver/ Mocking Bird 15/14 Fed Com #521H : REGULAR MAINTENANCE Job Date: 2025-10-17 08:09:44 Unit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 36; Drive Time: 2.0 hours; Site Hours: 6.0 hours; Job Hours: 8.0 hours; VCS-1513 : 10-17 unit was called in for having a bad screw so i drove to the shop filled up on oil and materials then dumped my waste oil and loaded up a G14 screw in my truck then fueled up an drove to location, an the way i had to stop an changed the tire on the crane truck after that we got too location an found that the unit was just pm so i drianed 3 gallons of oil from the coaleser then broke the unit down then pulled the inlet pipng off the unit and then the bad screw both motor an screw hubs were tore up along with the spider so i installed an new spider an hub on the motor then we prepped the new screw we found that the G14 hub key was broken so i drove to the woodford to grab a new key from issac then drove back to location finished prepping the screw an got it set on location, after that the crane truck waited on issac to show up to shim the screw and i left to another job. 1 150 motor hub 1 g14 screw hub 1 g14 spider 1 rebuilt G14 screw EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 1.0 ea 5569 Hub 150 HP Motor Side SCG14 EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 1.0 ea 5571 Spider SCG14 150 HP EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 1.0 ea 5570 Hub Screw Side SCG14 EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 1.0 ea 9341 Screw Rebuild SCG14 EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 25.0 gal 7922 Syncomp PG-220 EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 1.0 ea 7308 Filter, Hydraulic Oil. Used for NG21 EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 1.0 ea 9753 Silicone RTV 8oz Red EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 1.0 sq ft 9001 Gasket Material
at Intuit.Ipp.Exception.IdsExceptionManager.HandleException(IdsException idsException) at Intuit.Ipp.DataService.DataService.Add[T](T entity) at AwcConnect.Services.QuickBooksInvoiceService.SubmitInvoice(Invoice invoice) in C:\Users\johnc\source\repos\AwcConnect\Services\QuickBooksInvoiceService.cs:line 201
2025-09-08T18:52:00.0000000 Unable to find parse start location. Make sure there is a desciption line that starts with `vcs-1549:`.
{"TaxCodeId":"47","TaxRate":0.057083,"TaxCodeName":"Eddy County","Id":9172,"TimeStamp":"2025-09-01T09:45:27Z","wellName":"VCS-1549 FULLER 14/11 W1ED FED #1H","Username":"doug","otHours":0.0,"NoteText":"By: doug\n\nVCS-1549 FULLER 14/11 W1ED FED #1H : \n\nREGULAR MAINTENANCE \n\nJob Date: 2025-09-01 09:45:27 \n\nUnit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 34; Drive Time: .50 hours; Site Hours: 2.25 hours; Job Hours: 2.75 hours;\n\nVCS-1459 :\n9-1-25\nunit was needing a g21 bpv installed, arrived on site and unit was dua, verified no pressure in unit and it was isolated, removed hose and fittings from coalescer lid and removed block from top of tank and prepped to install bpv, during install while tightening up bolts for bpv had 1 that gave out so removed rest of fittings from lid, replaced lid with new one and bolted up, installed bpv onto lid and reconnected all fittings, and double checked tightness of all bolts, left unit down pending further site work by roustabouts,\ng 21 bpv\n20\u0022 coalescer lid\n\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n1.0 ea 7027 Minimum Pressure Valve NG20/21 Tanks \n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n1.0 ea 7741 20 Inch Coalescer Bolted Cover","SiteHours":2.25,"DriveTime":0.5,"Mileage":25.0,"parts":[{"commentNum":"105565","partNum":"7027","partName":"Minimum Pressure Valve NG20/21 Tanks ","quantity":1.0,"engUnit":"ea","unitPrice":1979.25,"markup":38.5},{"commentNum":"105565","partNum":"7741","partName":"20 Inch Coalescer Bolted Cover","quantity":1.0,"engUnit":"ea","unitPrice":1295.0,"markup":38.5}],"Total":4534.83625,"CustomerId":"356","ServiceId":"141","DriveTimeId":"156","MileageId":"143","ServiceRate":87.9,"DriveTimeRate":67.96,"MileageRate":1.4,"ItemId":"139"}
By: doug VCS-1549 FULLER 14/11 W1ED FED #1H : REGULAR MAINTENANCE Job Date: 2025-09-01 09:45:27 Unit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 34; Drive Time: .50 hours; Site Hours: 2.25 hours; Job Hours: 2.75 hours; VCS-1459 : 9-1-25 unit was needing a g21 bpv installed, arrived on site and unit was dua, verified no pressure in unit and it was isolated, removed hose and fittings from coalescer lid and removed block from top of tank and prepped to install bpv, during install while tightening up bolts for bpv had 1 that gave out so removed rest of fittings from lid, replaced lid with new one and bolted up, installed bpv onto lid and reconnected all fittings, and double checked tightness of all bolts, left unit down pending further site work by roustabouts, g 21 bpv 20" coalescer lid EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 1.0 ea 7027 Minimum Pressure Valve NG20/21 Tanks EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 1.0 ea 7741 20 Inch Coalescer Bolted Cover
at AwcConnect.Services.QuickBooksInvoiceService.SubmitInvoice(Invoice invoice) in C:\Users\johnc\source\repos\AwcConnect\Services\QuickBooksInvoiceService.cs:line 37
2025-08-11T19:45:16.0000000 There was an error while communicating with the Ids Server.
{"TaxCodeId":"47","TaxRate":0.057083,"TaxCodeName":"Eddy County","Id":8733,"TimeStamp":"2025-08-05T08:44:12Z","wellName":"VCS-1731 TOUGH OMBRES 6/4 BATTERY #1","Username":"dominic","otHours":0.0,"NoteText":"By: dominic\n\nVCS-1731 TOUGH OMBRES 6/4 BATTERY #1 : \n\nREGULAR MAINTENANCE \n\nJob Date: 2025-08-05 08:44:12 \n\nUnit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 20; Drive Time: 1.75 hours; Site Hours: 2.75 hours; Job Hours: 4.5 hours;\nHelper 1: Albert Dunseth\n\nVCS-1731 :\n8-5-25\nUH-287.0\nJSA#120\nCallout was oil leak tried to tighten it isn\u0027t helping.\n\nDrove to location got out so a lot of oil on skid saw where the leak was coming from so I shut unit down isolated unit checked all simulations all working correctly then drained all the oil out then took the nipple out and replaced it with a new fitting put teflon tape on the fitting then started putting the nipple back into place tighten it real good filled unit back up to 35-gallons of oil put down 90 soaker pads cleaned up mess turned unit back on monitoring unit.\n\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n35.0 gal 7922 Syncomp PG-220\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n50.0 ea 8436 990140 Grey Soaker Pads\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n40.0 ea 8436 990140 Grey Soaker Pads","SiteHours":2.75,"DriveTime":1.75,"Mileage":68.0,"parts":[{"commentNum":"104542","partNum":"7922","partName":"Syncomp PG-220","quantity":35.0,"engUnit":"gal","unitPrice":40.17,"markup":0},{"commentNum":"104542","partNum":"8436","partName":"990140 Grey Soaker Pads","quantity":50.0,"engUnit":"ea","unitPrice":0.8,"markup":38.5},{"commentNum":"104542","partNum":"8436","partName":"990140 Grey Soaker Pads","quantity":40.0,"engUnit":"ea","unitPrice":0.8,"markup":38.5}],"Total":1505.67,"CustomerId":"356","ServiceId":"141","DriveTimeId":"156","MileageId":"143","ServiceRate":87.9,"DriveTimeRate":67.96,"MileageRate":1.4,"ItemId":"139"}
By: dominic VCS-1731 TOUGH OMBRES 6/4 BATTERY #1 : REGULAR MAINTENANCE Job Date: 2025-08-05 08:44:12 Unit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 20; Drive Time: 1.75 hours; Site Hours: 2.75 hours; Job Hours: 4.5 hours; Helper 1: Albert Dunseth VCS-1731 : 8-5-25 UH-287.0 JSA#120 Callout was oil leak tried to tighten it isn't helping. Drove to location got out so a lot of oil on skid saw where the leak was coming from so I shut unit down isolated unit checked all simulations all working correctly then drained all the oil out then took the nipple out and replaced it with a new fitting put teflon tape on the fitting then started putting the nipple back into place tighten it real good filled unit back up to 35-gallons of oil put down 90 soaker pads cleaned up mess turned unit back on monitoring unit. EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 35.0 gal 7922 Syncomp PG-220 EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 50.0 ea 8436 990140 Grey Soaker Pads EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 40.0 ea 8436 990140 Grey Soaker Pads
at Intuit.Ipp.QueryFilter.QueryService`1.ExecuteIdsQuery(String idsQuery, QueryOperationType queryOperationType) at AwcConnect.Services.QuickBooksInvoiceService.GetCustomers(ServiceContext serviceContext) in C:\Users\johnc\source\repos\AwcConnect\Services\QuickBooksInvoiceService.cs:line 261 at AwcConnect.Services.QuickBooksInvoiceService.SubmitInvoice(Invoice invoice) in C:\Users\johnc\source\repos\AwcConnect\Services\QuickBooksInvoiceService.cs:line 60
2025-07-22T16:02:50.0000000 Unable to find parse start location. Make sure there is a desciption line that starts with `vcs-1486:`.
{"TaxCodeId":"47","TaxRate":0.057083,"TaxCodeName":"Eddy County","Id":8498,"TimeStamp":"2025-07-15T08:18:39Z","wellName":"VCS-1486 FULLER 13/12 BATTERY","Username":"nasser","otHours":0.0,"NoteText":"By: nasser\n\nVCS-1486 FULLER 13/12 : \n\nREGULAR MAINTENANCE \n\nJob Date: 2025-07-15 08:18:39 \n\nUnit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: PM; Truck #: 46; Drive Time: 1.0 hours; Site Hours: 1.0 hours; Job Hours: 2.0 hours;\nHelper 1: Joshua Oshley\n\n\nEngine Make: Electric, Cylinders: 1\nCylinder Compression: 0.0\n\nCS-1486 :\n07/15/25 Comment entry is for the Fuller 13/12 CS1486 PM, unit is not yet labled correctly\nUnit hours 24485\nJSA 406\nUnit was due for a pm. Drained oil. Changed oil filters. Checked and reinstalled coalescer filter. Refilled with oil. Checked actuators and dump operations. Greased electric motors. Restarted unit and monitored. all operations working properly.\nTwo of the 1849 oil filters, 32 gallons of PG220\n\n\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n32.0 gal 7922 Syncomp PG-220\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n2.0 ea 7308 Filter, Hydraulic Oil. Used for NG21","SiteHours":1.0,"DriveTime":1.0,"Mileage":8.0,"parts":[{"commentNum":"103696","partNum":"7922","partName":"Syncomp PG-220","quantity":32.0,"engUnit":"gal","unitPrice":40.17,"markup":0},{"commentNum":"103696","partNum":"7308","partName":"Filter, Hydraulic Oil. Used for NG21","quantity":2.0,"engUnit":"ea","unitPrice":175.0,"markup":38.5}],"Total":1770.19,"CustomerId":"356","ServiceId":"141","DriveTimeId":"156","MileageId":"143","ServiceRate":87.9,"DriveTimeRate":67.96,"MileageRate":1.4,"ItemId":"139"}
By: nasser VCS-1486 FULLER 13/12 : REGULAR MAINTENANCE Job Date: 2025-07-15 08:18:39 Unit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: PM; Truck #: 46; Drive Time: 1.0 hours; Site Hours: 1.0 hours; Job Hours: 2.0 hours; Helper 1: Joshua Oshley Engine Make: Electric, Cylinders: 1 Cylinder Compression: 0.0 CS-1486 : 07/15/25 Comment entry is for the Fuller 13/12 CS1486 PM, unit is not yet labled correctly Unit hours 24485 JSA 406 Unit was due for a pm. Drained oil. Changed oil filters. Checked and reinstalled coalescer filter. Refilled with oil. Checked actuators and dump operations. Greased electric motors. Restarted unit and monitored. all operations working properly. Two of the 1849 oil filters, 32 gallons of PG220 EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 32.0 gal 7922 Syncomp PG-220 EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 2.0 ea 7308 Filter, Hydraulic Oil. Used for NG21
at AwcConnect.Services.QuickBooksInvoiceService.SubmitInvoice(Invoice invoice) in C:\Users\johnc\source\repos\AwcConnect\Services\QuickBooksInvoiceService.cs:line 37
2025-07-15T16:21:59.0000000 Unable to find parse start location. Make sure there is a desciption line that starts with `vcs-1546:`.
{"TaxCodeId":"47","TaxRate":0.0525,"TaxCodeName":"Lea County","Id":8393,"TimeStamp":"2025-07-09T07:38:07Z","wellName":"VCS-1546 Bilbrey 34/27 Battery 2","Username":"terry","otHours":0.0,"NoteText":"By: terry\n\nVCS-1546 Bilbrey 34/27 Battery 2 : \n\nREGULAR MAINTENANCE \n\nJob Date: 2025-07-09 07:38:07 \n\nUnit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 33; Drive Time: 2.0 hours; Site Hours: 2.0 hours; Job Hours: 4.0 hours;\n\nVCS-1733 :\nJob date 7-9-25\nJSA# 50MH\nUnit hrs 16190\nCallout for failed to reach minimum speed. Once on location troublshot issue to be bad VFD. Performed LOTO procedures. Removed VFD and installed new one. Removed LOTO. Turned power on and set parameters. Tested all operations. Unit left down due to high line pressure.\n\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n1.0 ea 5562 Drive Hitachi","SiteHours":2.0,"DriveTime":2.0,"Mileage":87.0,"parts":[{"commentNum":"103420","partNum":"5562","partName":"Drive Hitachi","quantity":1.0,"engUnit":"ea","unitPrice":7534.0,"markup":38.5}],"Total":10434.59,"CustomerId":"356","ServiceId":"141","DriveTimeId":"156","MileageId":"143","ServiceRate":87.9,"DriveTimeRate":67.96,"MileageRate":1.4,"ItemId":"139"}
By: terry VCS-1546 Bilbrey 34/27 Battery 2 : REGULAR MAINTENANCE Job Date: 2025-07-09 07:38:07 Unit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 33; Drive Time: 2.0 hours; Site Hours: 2.0 hours; Job Hours: 4.0 hours; VCS-1733 : Job date 7-9-25 JSA# 50MH Unit hrs 16190 Callout for failed to reach minimum speed. Once on location troublshot issue to be bad VFD. Performed LOTO procedures. Removed VFD and installed new one. Removed LOTO. Turned power on and set parameters. Tested all operations. Unit left down due to high line pressure. EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 1.0 ea 5562 Drive Hitachi
at AwcConnect.Services.QuickBooksInvoiceService.SubmitInvoice(Invoice invoice) in C:\Users\johnc\source\repos\AwcConnect\Services\QuickBooksInvoiceService.cs:line 37
2025-07-15T16:21:28.0000000 Unable to find parse start location. Make sure there is a desciption line that starts with `vcs-1546:`.
{"TaxCodeId":"47","TaxRate":0.0525,"TaxCodeName":"Lea County","Id":8393,"TimeStamp":"2025-07-09T07:38:07Z","wellName":"VCS-1546 Bilbrey 34/27 Battery 2","Username":"terry","otHours":0.0,"NoteText":"By: terry\n\nVCS-1546 Bilbrey 34/27 Battery 2 : \n\nREGULAR MAINTENANCE \n\nJob Date: 2025-07-09 07:38:07 \n\nUnit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 33; Drive Time: 2.0 hours; Site Hours: 2.0 hours; Job Hours: 4.0 hours;\n\nVCS-1733 :\nJob date 7-9-25\nJSA# 50MH\nUnit hrs 16190\nCallout for failed to reach minimum speed. Once on location troublshot issue to be bad VFD. Performed LOTO procedures. Removed VFD and installed new one. Removed LOTO. Turned power on and set parameters. Tested all operations. Unit left down due to high line pressure.\n\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n1.0 ea 5562 Drive Hitachi","SiteHours":2.0,"DriveTime":2.0,"Mileage":87.0,"parts":[{"commentNum":"103420","partNum":"5562","partName":"Drive Hitachi","quantity":1.0,"engUnit":"ea","unitPrice":7534.0,"markup":38.5}],"Total":10434.59,"CustomerId":"356","ServiceId":"141","DriveTimeId":"156","MileageId":"143","ServiceRate":87.9,"DriveTimeRate":67.96,"MileageRate":1.4,"ItemId":"139"}
By: terry VCS-1546 Bilbrey 34/27 Battery 2 : REGULAR MAINTENANCE Job Date: 2025-07-09 07:38:07 Unit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 33; Drive Time: 2.0 hours; Site Hours: 2.0 hours; Job Hours: 4.0 hours; VCS-1733 : Job date 7-9-25 JSA# 50MH Unit hrs 16190 Callout for failed to reach minimum speed. Once on location troublshot issue to be bad VFD. Performed LOTO procedures. Removed VFD and installed new one. Removed LOTO. Turned power on and set parameters. Tested all operations. Unit left down due to high line pressure. EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 1.0 ea 5562 Drive Hitachi
at AwcConnect.Services.QuickBooksInvoiceService.SubmitInvoice(Invoice invoice) in C:\Users\johnc\source\repos\AwcConnect\Services\QuickBooksInvoiceService.cs:line 37
2025-07-15T16:20:58.0000000 Unable to find parse start location. Make sure there is a desciption line that starts with `vcs-1546:`.
{"TaxCodeId":"47","TaxRate":0.0525,"TaxCodeName":"Lea County","Id":8393,"TimeStamp":"2025-07-09T07:38:07Z","wellName":"VCS-1546 Bilbrey 34/27 Battery 2","Username":"terry","otHours":0.0,"NoteText":"By: terry\n\nVCS-1546 Bilbrey 34/27 Battery 2 : \n\nREGULAR MAINTENANCE \n\nJob Date: 2025-07-09 07:38:07 \n\nUnit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 33; Drive Time: 2.0 hours; Site Hours: 2.0 hours; Job Hours: 4.0 hours;\n\nVCS-1733 :\nJob date 7-9-25\nJSA# 50MH\nUnit hrs 16190\nCallout for failed to reach minimum speed. Once on location troublshot issue to be bad VFD. Performed LOTO procedures. Removed VFD and installed new one. Removed LOTO. Turned power on and set parameters. Tested all operations. Unit left down due to high line pressure.\n\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n1.0 ea 5562 Drive Hitachi","SiteHours":2.0,"DriveTime":2.0,"Mileage":87.0,"parts":[{"commentNum":"103420","partNum":"5562","partName":"Drive Hitachi","quantity":1.0,"engUnit":"ea","unitPrice":7534.0,"markup":38.5}],"Total":10434.59,"CustomerId":"356","ServiceId":"141","DriveTimeId":"156","MileageId":"143","ServiceRate":87.9,"DriveTimeRate":67.96,"MileageRate":1.4,"ItemId":"139"}
By: terry VCS-1546 Bilbrey 34/27 Battery 2 : REGULAR MAINTENANCE Job Date: 2025-07-09 07:38:07 Unit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 33; Drive Time: 2.0 hours; Site Hours: 2.0 hours; Job Hours: 4.0 hours; VCS-1733 : Job date 7-9-25 JSA# 50MH Unit hrs 16190 Callout for failed to reach minimum speed. Once on location troublshot issue to be bad VFD. Performed LOTO procedures. Removed VFD and installed new one. Removed LOTO. Turned power on and set parameters. Tested all operations. Unit left down due to high line pressure. EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 1.0 ea 5562 Drive Hitachi
at AwcConnect.Services.QuickBooksInvoiceService.SubmitInvoice(Invoice invoice) in C:\Users\johnc\source\repos\AwcConnect\Services\QuickBooksInvoiceService.cs:line 37
2025-07-15T16:20:38.0000000 Unable to find parse start location. Make sure there is a desciption line that starts with `vcs-1546:`.
{"TaxCodeId":"47","TaxRate":0.057083,"TaxCodeName":"Eddy County","Id":8393,"TimeStamp":"2025-07-09T07:38:07Z","wellName":"VCS-1546 Bilbrey 34/27 Battery 2","Username":"terry","otHours":0.0,"NoteText":"By: terry\n\nVCS-1546 Bilbrey 34/27 Battery 2 : \n\nREGULAR MAINTENANCE \n\nJob Date: 2025-07-09 07:38:07 \n\nUnit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 33; Drive Time: 2.0 hours; Site Hours: 2.0 hours; Job Hours: 4.0 hours;\n\nVCS-1733 :\nJob date 7-9-25\nJSA# 50MH\nUnit hrs 16190\nCallout for failed to reach minimum speed. Once on location troublshot issue to be bad VFD. Performed LOTO procedures. Removed VFD and installed new one. Removed LOTO. Turned power on and set parameters. Tested all operations. Unit left down due to high line pressure.\n\n\n EDIT ADDITION: PARTS / SUPPLIES\n--------------------------------------------------------------------------\n Quantity | Number | Name\n--------------------------------------------------------------------------\n\n1.0 ea 5562 Drive Hitachi","SiteHours":2.0,"DriveTime":2.0,"Mileage":87.0,"parts":[{"commentNum":"103420","partNum":"5562","partName":"Drive Hitachi","quantity":1.0,"engUnit":"ea","unitPrice":7534.0,"markup":38.5}],"Total":10434.59,"CustomerId":"356","ServiceId":"141","DriveTimeId":"156","MileageId":"143","ServiceRate":87.9,"DriveTimeRate":67.96,"MileageRate":1.4,"ItemId":"139"}
By: terry VCS-1546 Bilbrey 34/27 Battery 2 : REGULAR MAINTENANCE Job Date: 2025-07-09 07:38:07 Unit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 33; Drive Time: 2.0 hours; Site Hours: 2.0 hours; Job Hours: 4.0 hours; VCS-1733 : Job date 7-9-25 JSA# 50MH Unit hrs 16190 Callout for failed to reach minimum speed. Once on location troublshot issue to be bad VFD. Performed LOTO procedures. Removed VFD and installed new one. Removed LOTO. Turned power on and set parameters. Tested all operations. Unit left down due to high line pressure. EDIT ADDITION: PARTS / SUPPLIES -------------------------------------------------------------------------- Quantity | Number | Name -------------------------------------------------------------------------- 1.0 ea 5562 Drive Hitachi
at AwcConnect.Services.QuickBooksInvoiceService.SubmitInvoice(Invoice invoice) in C:\Users\johnc\source\repos\AwcConnect\Services\QuickBooksInvoiceService.cs:line 37
2025-06-24T19:30:44.0000000 BadRequest. Details: The account period has closed and the account books cannot be updated through through the QBO Services API. Please use the QBO website to make these changes. ,
{"TaxCodeId":"47","TaxRate":0.0,"TaxCodeName":"TX","Id":7976,"TimeStamp":"2014-12-20T10:45:58Z","wellName":"VCS-1728 ZUMA 3 #B203CN BATTERY","Username":"blaise","otHours":0.0,"NoteText":"By: blaise\n\nVCS-1728 ZUMA 3 #B203CN BATTERY : \n\nREGULAR MAINTENANCE \n\nJob Date: 2025-06-21 12:07:12 \n\nUnit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 12; Drive Time: 2.50 hours; Site Hours: 1.50 hours; Job Hours: 4.0 hours;\n\nVCS-1728 :\nJob date 6-21-25\nCs1728\nUh-383\nJsa-753\nCallout for Dp high high. Shut unit down and drained pressure. Added 10 gallons pg 220. Found leak on fittings on coalescer lid so fixed them up. Checked all wiring in plc cabinet and tightened all connections. Checked wiring at all transducers to be good. Ran and tested unit with no kill triggering. Checked all other operations to be correct.\n","SiteHours":1.5,"DriveTime":2.5,"Mileage":0.0,"parts":[],"Total":0,"CustomerId":"356","ServiceId":"141","DriveTimeId":"156","MileageId":"143","ServiceRate":87.9,"DriveTimeRate":67.96,"MileageRate":1.4,"ItemId":"139"}
By: blaise VCS-1728 ZUMA 3 #B203CN BATTERY : REGULAR MAINTENANCE Job Date: 2025-06-21 12:07:12 Unit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 12; Drive Time: 2.50 hours; Site Hours: 1.50 hours; Job Hours: 4.0 hours; VCS-1728 : Job date 6-21-25 Cs1728 Uh-383 Jsa-753 Callout for Dp high high. Shut unit down and drained pressure. Added 10 gallons pg 220. Found leak on fittings on coalescer lid so fixed them up. Checked all wiring in plc cabinet and tightened all connections. Checked wiring at all transducers to be good. Ran and tested unit with no kill triggering. Checked all other operations to be correct.
at Intuit.Ipp.Exception.IdsExceptionManager.HandleException(IdsException idsException) at Intuit.Ipp.DataService.DataService.Add[T](T entity) at AwcConnect.Services.QuickBooksInvoiceService.SubmitInvoice(Invoice invoice) in C:\Users\johnc\source\repos\AwcConnect\Services\QuickBooksInvoiceService.cs:line 201
2025-06-24T19:26:31.0000000 BadRequest. Details: The account period has closed and the account books cannot be updated through through the QBO Services API. Please use the QBO website to make these changes. ,
{"TaxCodeId":"47","TaxRate":0.0,"TaxCodeName":"TX","Id":7976,"TimeStamp":"2014-12-20T10:45:58Z","wellName":"VCS-1728 ZUMA 3 #B203CN BATTERY","Username":"blaise","otHours":0.0,"NoteText":"By: blaise\n\nVCS-1728 ZUMA 3 #B203CN BATTERY : \n\nREGULAR MAINTENANCE \n\nJob Date: 2025-06-21 12:07:12 \n\nUnit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 12; Drive Time: 2.50 hours; Site Hours: 1.50 hours; Job Hours: 4.0 hours;\n\nVCS-1728 :\nJob date 6-21-25\nCs1728\nUh-383\nJsa-753\nCallout for Dp high high. Shut unit down and drained pressure. Added 10 gallons pg 220. Found leak on fittings on coalescer lid so fixed them up. Checked all wiring in plc cabinet and tightened all connections. Checked wiring at all transducers to be good. Ran and tested unit with no kill triggering. Checked all other operations to be correct.\n","SiteHours":1.5,"DriveTime":2.5,"Mileage":0.0,"parts":[],"Total":0,"CustomerId":"356","ServiceId":"141","DriveTimeId":"156","MileageId":"143","ServiceRate":87.9,"DriveTimeRate":67.96,"MileageRate":1.4,"ItemId":"139"}
By: blaise VCS-1728 ZUMA 3 #B203CN BATTERY : REGULAR MAINTENANCE Job Date: 2025-06-21 12:07:12 Unit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 12; Drive Time: 2.50 hours; Site Hours: 1.50 hours; Job Hours: 4.0 hours; VCS-1728 : Job date 6-21-25 Cs1728 Uh-383 Jsa-753 Callout for Dp high high. Shut unit down and drained pressure. Added 10 gallons pg 220. Found leak on fittings on coalescer lid so fixed them up. Checked all wiring in plc cabinet and tightened all connections. Checked wiring at all transducers to be good. Ran and tested unit with no kill triggering. Checked all other operations to be correct.
at Intuit.Ipp.Exception.IdsExceptionManager.HandleException(IdsException idsException) at Intuit.Ipp.DataService.DataService.Add[T](T entity) at AwcConnect.Services.QuickBooksInvoiceService.SubmitInvoice(Invoice invoice) in C:\Users\johnc\source\repos\AwcConnect\Services\QuickBooksInvoiceService.cs:line 201
2025-06-24T19:25:11.0000000 BadRequest. Details: The account period has closed and the account books cannot be updated through through the QBO Services API. Please use the QBO website to make these changes. ,
{"TaxCodeId":"47","TaxRate":0.0,"TaxCodeName":"TX","Id":7976,"TimeStamp":"2014-12-20T10:45:58Z","wellName":"VCS-1728 ZUMA 3 #B203CN BATTERY","Username":"blaise","otHours":0.0,"NoteText":"By: blaise\n\nVCS-1728 ZUMA 3 #B203CN BATTERY : \n\nREGULAR MAINTENANCE \n\nJob Date: 2025-06-21 12:07:12 \n\nUnit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 12; Drive Time: 2.50 hours; Site Hours: 1.50 hours; Job Hours: 4.0 hours;\n\nVCS-1728 :\nJob date 6-21-25\nCs1728\nUh-383\nJsa-753\nCallout for Dp high high. Shut unit down and drained pressure. Added 10 gallons pg 220. Found leak on fittings on coalescer lid so fixed them up. Checked all wiring in plc cabinet and tightened all connections. Checked wiring at all transducers to be good. Ran and tested unit with no kill triggering. Checked all other operations to be correct.\n","SiteHours":1.5,"DriveTime":2.5,"Mileage":0.0,"parts":[],"Total":0,"CustomerId":"356","ServiceId":"141","DriveTimeId":"156","MileageId":"143","ServiceRate":87.9,"DriveTimeRate":67.96,"MileageRate":1.4,"ItemId":"139"}
By: blaise VCS-1728 ZUMA 3 #B203CN BATTERY : REGULAR MAINTENANCE Job Date: 2025-06-21 12:07:12 Unit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 12; Drive Time: 2.50 hours; Site Hours: 1.50 hours; Job Hours: 4.0 hours; VCS-1728 : Job date 6-21-25 Cs1728 Uh-383 Jsa-753 Callout for Dp high high. Shut unit down and drained pressure. Added 10 gallons pg 220. Found leak on fittings on coalescer lid so fixed them up. Checked all wiring in plc cabinet and tightened all connections. Checked wiring at all transducers to be good. Ran and tested unit with no kill triggering. Checked all other operations to be correct.
at Intuit.Ipp.Exception.IdsExceptionManager.HandleException(IdsException idsException) at Intuit.Ipp.DataService.DataService.Add[T](T entity) at AwcConnect.Services.QuickBooksInvoiceService.SubmitInvoice(Invoice invoice) in C:\Users\johnc\source\repos\AwcConnect\Services\QuickBooksInvoiceService.cs:line 201
2025-06-24T19:23:57.0000000 BadRequest. Details: The account period has closed and the account books cannot be updated through through the QBO Services API. Please use the QBO website to make these changes. ,
{"TaxCodeId":"47","TaxRate":0.0,"TaxCodeName":"TX","Id":7976,"TimeStamp":"2014-12-20T10:45:58Z","wellName":"VCS-1728 ZUMA 3 #B203CN BATTERY","Username":"blaise","otHours":0.0,"NoteText":"By: blaise\n\nVCS-1728 ZUMA 3 #B203CN BATTERY : \n\nREGULAR MAINTENANCE \n\nJob Date: 2025-06-21 12:07:12 \n\nUnit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 12; Drive Time: 2.50 hours; Site Hours: 1.50 hours; Job Hours: 4.0 hours;\n\nVCS-1728 :\nJob date 6-21-25\nCs1728\nUh-383\nJsa-753\nCallout for Dp high high. Shut unit down and drained pressure. Added 10 gallons pg 220. Found leak on fittings on coalescer lid so fixed them up. Checked all wiring in plc cabinet and tightened all connections. Checked wiring at all transducers to be good. Ran and tested unit with no kill triggering. Checked all other operations to be correct.\n","SiteHours":1.5,"DriveTime":2.5,"Mileage":0.0,"parts":[],"Total":0,"CustomerId":"356","ServiceId":"141","DriveTimeId":"156","MileageId":"143","ServiceRate":87.9,"DriveTimeRate":67.96,"MileageRate":1.4,"ItemId":"139"}
By: blaise VCS-1728 ZUMA 3 #B203CN BATTERY : REGULAR MAINTENANCE Job Date: 2025-06-21 12:07:12 Unit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 12; Drive Time: 2.50 hours; Site Hours: 1.50 hours; Job Hours: 4.0 hours; VCS-1728 : Job date 6-21-25 Cs1728 Uh-383 Jsa-753 Callout for Dp high high. Shut unit down and drained pressure. Added 10 gallons pg 220. Found leak on fittings on coalescer lid so fixed them up. Checked all wiring in plc cabinet and tightened all connections. Checked wiring at all transducers to be good. Ran and tested unit with no kill triggering. Checked all other operations to be correct.
at Intuit.Ipp.Exception.IdsExceptionManager.HandleException(IdsException idsException) at Intuit.Ipp.DataService.DataService.Add[T](T entity) at AwcConnect.Services.QuickBooksInvoiceService.SubmitInvoice(Invoice invoice) in C:\Users\johnc\source\repos\AwcConnect\Services\QuickBooksInvoiceService.cs:line 201
2025-06-24T19:23:23.0000000 BadRequest. Details: The account period has closed and the account books cannot be updated through through the QBO Services API. Please use the QBO website to make these changes. ,
{"TaxCodeId":"47","TaxRate":0.0,"TaxCodeName":"TX","Id":7976,"TimeStamp":"2014-12-20T10:45:58Z","wellName":"VCS-1728 ZUMA 3 #B203CN BATTERY","Username":"blaise","otHours":0.0,"NoteText":"By: blaise\n\nVCS-1728 ZUMA 3 #B203CN BATTERY : \n\nREGULAR MAINTENANCE \n\nJob Date: 2025-06-21 12:07:12 \n\nUnit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 12; Drive Time: 2.50 hours; Site Hours: 1.50 hours; Job Hours: 4.0 hours;\n\nVCS-1728 :\nJob date 6-21-25\nCs1728\nUh-383\nJsa-753\nCallout for Dp high high. Shut unit down and drained pressure. Added 10 gallons pg 220. Found leak on fittings on coalescer lid so fixed them up. Checked all wiring in plc cabinet and tightened all connections. Checked wiring at all transducers to be good. Ran and tested unit with no kill triggering. Checked all other operations to be correct.\n","SiteHours":1.5,"DriveTime":2.5,"Mileage":0.0,"parts":[],"Total":0,"CustomerId":"356","ServiceId":"141","DriveTimeId":"156","MileageId":"143","ServiceRate":87.9,"DriveTimeRate":67.96,"MileageRate":1.4,"ItemId":"139"}
By: blaise VCS-1728 ZUMA 3 #B203CN BATTERY : REGULAR MAINTENANCE Job Date: 2025-06-21 12:07:12 Unit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 12; Drive Time: 2.50 hours; Site Hours: 1.50 hours; Job Hours: 4.0 hours; VCS-1728 : Job date 6-21-25 Cs1728 Uh-383 Jsa-753 Callout for Dp high high. Shut unit down and drained pressure. Added 10 gallons pg 220. Found leak on fittings on coalescer lid so fixed them up. Checked all wiring in plc cabinet and tightened all connections. Checked wiring at all transducers to be good. Ran and tested unit with no kill triggering. Checked all other operations to be correct.
at Intuit.Ipp.Exception.IdsExceptionManager.HandleException(IdsException idsException) at Intuit.Ipp.DataService.DataService.Add[T](T entity) at AwcConnect.Services.QuickBooksInvoiceService.SubmitInvoice(Invoice invoice) in C:\Users\johnc\source\repos\AwcConnect\Services\QuickBooksInvoiceService.cs:line 201
2025-06-24T19:19:32.0000000 BadRequest. Details: The account period has closed and the account books cannot be updated through through the QBO Services API. Please use the QBO website to make these changes. ,
{"TaxCodeId":"47","TaxRate":0.0,"TaxCodeName":"TX","Id":7976,"TimeStamp":"2014-12-20T10:45:58Z","wellName":"VCS-1728 ZUMA 3 #B203CN BATTERY","Username":"blaise","otHours":0.0,"NoteText":"By: blaise\n\nVCS-1728 ZUMA 3 #B203CN BATTERY : \n\nREGULAR MAINTENANCE \n\nJob Date: 2025-06-21 12:07:12 \n\nUnit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 12; Drive Time: 2.50 hours; Site Hours: 1.50 hours; Job Hours: 4.0 hours;\n\nVCS-1728 :\nJob date 6-21-25\nCs1728\nUh-383\nJsa-753\nCallout for Dp high high. Shut unit down and drained pressure. Added 10 gallons pg 220. Found leak on fittings on coalescer lid so fixed them up. Checked all wiring in plc cabinet and tightened all connections. Checked wiring at all transducers to be good. Ran and tested unit with no kill triggering. Checked all other operations to be correct.\n","SiteHours":1.5,"DriveTime":2.5,"Mileage":0.0,"parts":[],"Total":0,"CustomerId":"356","ServiceId":"141","DriveTimeId":"156","MileageId":"143","ServiceRate":87.9,"DriveTimeRate":67.96,"MileageRate":1.4,"ItemId":"139"}
By: blaise VCS-1728 ZUMA 3 #B203CN BATTERY : REGULAR MAINTENANCE Job Date: 2025-06-21 12:07:12 Unit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 12; Drive Time: 2.50 hours; Site Hours: 1.50 hours; Job Hours: 4.0 hours; VCS-1728 : Job date 6-21-25 Cs1728 Uh-383 Jsa-753 Callout for Dp high high. Shut unit down and drained pressure. Added 10 gallons pg 220. Found leak on fittings on coalescer lid so fixed them up. Checked all wiring in plc cabinet and tightened all connections. Checked wiring at all transducers to be good. Ran and tested unit with no kill triggering. Checked all other operations to be correct.
at Intuit.Ipp.Exception.IdsExceptionManager.HandleException(IdsException idsException) at Intuit.Ipp.DataService.DataService.Add[T](T entity) at AwcConnect.Services.QuickBooksInvoiceService.SubmitInvoice(Invoice invoice) in C:\Users\johnc\source\repos\AwcConnect\Services\QuickBooksInvoiceService.cs:line 201
2025-06-24T19:16:41.0000000 BadRequest. Details: The account period has closed and the account books cannot be updated through through the QBO Services API. Please use the QBO website to make these changes. ,
{"TaxCodeId":"47","TaxRate":0.0,"TaxCodeName":"TX","Id":7976,"TimeStamp":"2014-12-20T10:45:58Z","wellName":"VCS-1728 ZUMA 3 #B203CN BATTERY","Username":"blaise","otHours":0.0,"NoteText":"By: blaise\n\nVCS-1728 ZUMA 3 #B203CN BATTERY : \n\nREGULAR MAINTENANCE \n\nJob Date: 2025-06-21 12:07:12 \n\nUnit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 12; Drive Time: 2.50 hours; Site Hours: 1.50 hours; Job Hours: 4.0 hours;\n\nVCS-1728 :\nJob date 6-21-25\nCs1728\nUh-383\nJsa-753\nCallout for Dp high high. Shut unit down and drained pressure. Added 10 gallons pg 220. Found leak on fittings on coalescer lid so fixed them up. Checked all wiring in plc cabinet and tightened all connections. Checked wiring at all transducers to be good. Ran and tested unit with no kill triggering. Checked all other operations to be correct.\n","SiteHours":1.5,"DriveTime":2.5,"Mileage":0.0,"parts":[],"Total":0,"CustomerId":"356","ServiceId":"141","DriveTimeId":"156","MileageId":"143","ServiceRate":87.9,"DriveTimeRate":67.96,"MileageRate":1.4,"ItemId":"139"}
By: blaise VCS-1728 ZUMA 3 #B203CN BATTERY : REGULAR MAINTENANCE Job Date: 2025-06-21 12:07:12 Unit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 12; Drive Time: 2.50 hours; Site Hours: 1.50 hours; Job Hours: 4.0 hours; VCS-1728 : Job date 6-21-25 Cs1728 Uh-383 Jsa-753 Callout for Dp high high. Shut unit down and drained pressure. Added 10 gallons pg 220. Found leak on fittings on coalescer lid so fixed them up. Checked all wiring in plc cabinet and tightened all connections. Checked wiring at all transducers to be good. Ran and tested unit with no kill triggering. Checked all other operations to be correct.
at Intuit.Ipp.Exception.IdsExceptionManager.HandleException(IdsException idsException) at Intuit.Ipp.DataService.DataService.Add[T](T entity) at AwcConnect.Services.QuickBooksInvoiceService.SubmitInvoice(Invoice invoice) in C:\Users\johnc\source\repos\AwcConnect\Services\QuickBooksInvoiceService.cs:line 201
2025-04-01T21:36:36.0000000 Unable to find parse start location. Make sure there is a desciption line that starts with `vcs-1551:`.
{"TaxCodeId":"47","TaxRate":0.057083,"TaxCodeName":"Eddy County","Id":6879,"TimeStamp":"2025-03-26T13:11:32Z","wellName":"VCS-1551 RIO GRANDE 2/1 BATTERY","Username":"davidc","otHours":0.0,"NoteText":"By: davidc\n\nVCS-1551 RIO GRANDE 2/1 BATTERY : \n\nREGULAR MAINTENANCE \n\nJob Date: 2025-03-26 13:11:32 \n\nUnit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 34; Drive Time: .50 hours; Site Hours: 1.50 hours; Job Hours: 2.0 hours;\n\nVCS-1434 :\n3-20-25\nCS-1551\nUH-13054\nJSA-1028dec\nDT-n/a\nBOL-9;15am\nCall out to trouble shoot a leak. We determined cooler needed to be replaced so we shut it in and we will get back with another one. I communicated with flow back and he is getting with yal to see if we want to run it like this until we get another one out here. \n","SiteHours":1.5,"DriveTime":0.5,"Mileage":19.0,"parts":[],"Total":0,"CustomerId":"356","ServiceId":"141","DriveTimeId":"156","MileageId":"143","ServiceRate":87.9,"DriveTimeRate":67.96,"MileageRate":1.4,"ItemId":"139"}
By: davidc VCS-1551 RIO GRANDE 2/1 BATTERY : REGULAR MAINTENANCE Job Date: 2025-03-26 13:11:32 Unit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 34; Drive Time: .50 hours; Site Hours: 1.50 hours; Job Hours: 2.0 hours; VCS-1434 : 3-20-25 CS-1551 UH-13054 JSA-1028dec DT-n/a BOL-9;15am Call out to trouble shoot a leak. We determined cooler needed to be replaced so we shut it in and we will get back with another one. I communicated with flow back and he is getting with yal to see if we want to run it like this until we get another one out here.
at AwcConnect.Services.QuickBooksInvoiceService.SubmitInvoice(Invoice invoice) in C:\Users\johnc\source\repos\AwcConnect\Services\QuickBooksInvoiceService.cs:line 37
2025-04-01T21:36:20.0000000 Unable to find parse start location. Make sure there is a desciption line that starts with `vcs-1551:`.
{"TaxCodeId":"47","TaxRate":0.057083,"TaxCodeName":"Eddy County","Id":6879,"TimeStamp":"2025-03-26T13:11:32Z","wellName":"VCS-1551 RIO GRANDE 2/1 BATTERY","Username":"davidc","otHours":0.0,"NoteText":"By: davidc\n\nVCS-1551 RIO GRANDE 2/1 BATTERY : \n\nREGULAR MAINTENANCE \n\nJob Date: 2025-03-26 13:11:32 \n\nUnit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 34; Drive Time: .50 hours; Site Hours: 1.50 hours; Job Hours: 2.0 hours;\n\nVCS-1434 :\n3-20-25\nCS-1551\nUH-13054\nJSA-1028dec\nDT-n/a\nBOL-9;15am\nCall out to trouble shoot a leak. We determined cooler needed to be replaced so we shut it in and we will get back with another one. I communicated with flow back and he is getting with yal to see if we want to run it like this until we get another one out here. \n","SiteHours":1.5,"DriveTime":0.5,"Mileage":19.0,"parts":[],"Total":0,"CustomerId":"356","ServiceId":"141","DriveTimeId":"156","MileageId":"143","ServiceRate":87.9,"DriveTimeRate":67.96,"MileageRate":1.4,"ItemId":"139"}
By: davidc VCS-1551 RIO GRANDE 2/1 BATTERY : REGULAR MAINTENANCE Job Date: 2025-03-26 13:11:32 Unit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 34; Drive Time: .50 hours; Site Hours: 1.50 hours; Job Hours: 2.0 hours; VCS-1434 : 3-20-25 CS-1551 UH-13054 JSA-1028dec DT-n/a BOL-9;15am Call out to trouble shoot a leak. We determined cooler needed to be replaced so we shut it in and we will get back with another one. I communicated with flow back and he is getting with yal to see if we want to run it like this until we get another one out here.
at AwcConnect.Services.QuickBooksInvoiceService.SubmitInvoice(Invoice invoice) in C:\Users\johnc\source\repos\AwcConnect\Services\QuickBooksInvoiceService.cs:line 37
2025-03-27T14:47:40.0000000 Unable to find parse start location. Make sure there is a desciption line that starts with `vcs-1492:`.
{"TaxCodeId":"47","TaxRate":0.0525,"TaxCodeName":"Lea County","Id":6833,"TimeStamp":"2025-03-21T12:17:28Z","wellName":"VCS-1492 Red Hills West 22 W0AP Fed Com 2H Battery ","Username":"davidc","otHours":0.0,"NoteText":"By: davidc\n\nVCS-1492 Red Hills West 22 W0AP Fed Com 2H Battery : \n\nREGULAR MAINTENANCE \n\nJob Date: 2025-03-21 12:17:28 \n\nUnit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 34; Drive Time: 2.0 hours; Site Hours: 2.0 hours; Job Hours: 4.0 hours;\n\nVCS-1406 :\n3-21-25\nCS-1492\nUH-23596\nJSA-1032dec\nDT-n/a\nBOL-tbd\nCall out for unit over amping. Unit locked up so we seperated the motor from the screw and bumped unit to determine the screw compressor locked up. Called for return with screw.\n","SiteHours":2.0,"DriveTime":2.0,"Mileage":80.0,"parts":[],"Total":0,"CustomerId":"356","ServiceId":"141","DriveTimeId":"156","MileageId":"143","ServiceRate":87.9,"DriveTimeRate":67.96,"MileageRate":1.4,"ItemId":"139"}
By: davidc VCS-1492 Red Hills West 22 W0AP Fed Com 2H Battery : REGULAR MAINTENANCE Job Date: 2025-03-21 12:17:28 Unit Hours: 0 hours; Hours Until PM: 0 hours; Bill To: Call Out; Truck #: 34; Drive Time: 2.0 hours; Site Hours: 2.0 hours; Job Hours: 4.0 hours; VCS-1406 : 3-21-25 CS-1492 UH-23596 JSA-1032dec DT-n/a BOL-tbd Call out for unit over amping. Unit locked up so we seperated the motor from the screw and bumped unit to determine the screw compressor locked up. Called for return with screw.
at AwcConnect.Services.QuickBooksInvoiceService.SubmitInvoice(Invoice invoice) in C:\Users\johnc\source\repos\AwcConnect\Services\QuickBooksInvoiceService.cs:line 37
An unhandled error has occurred. Reload 🗙